Fusion Air Purge Trouble Shooting
This article features a selection of common problems applicators have experienced with the Fusion Air Purge spray gun along with the cause and solution.
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Gun does not fully actuate when triggered | Safety lock engaged | Disengage safety lock |
Plugged muffler | Clean | |
Damaged air valve o-rings | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Fluid does not spray when gun is fully actuated | Closed fluid valves | Open |
Plugged impingement ports | Clean | |
Plugged check valves | Clean |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Gun actuates slowly | Plugged muffler | Clean |
Damaged piston o-rings | Replace | |
Dirty air valve, or damaged o-rings | Clean air valve or replace o-rings |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Gun delays, then actuates abruptly | Cured material around side seals | Inspect side seals and mix chamber for scratches, Replace |
Retaining ring not bottomed out | Tighten retaining ring until bottomed out |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Loss of round pattern | Dirty mix chamber nozzle | Clean |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Loss of flat pattern | Plugged spray tip | Clean in compatible solvent |
Worn tip | Replace | |
Dirty mix chamber nozzle | Clean |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Leakage between flat tip and mix chamber | Damaged side seals | Replace |
Damaged mix chamber | Replace | |
Damaged side seal o-rings | Replace | |
Tightened air cap with fluid valves open | Close valves first |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Fluid mist from mix chamber or air cap | Damaged side seals | Replace |
Damaged mix chamber | Replace | |
Damaged side seal o-rings | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Excessive overspray | Too much cleanoff air | Reduce |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Rapid buildup of material on air cap | Plugged air cap holes | Clean |
Too little cleanoff air | Increase | |
Damaged/missing fluid housing o-ring | Replace | |
Damaged front o-ring | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Reduced cleanoff air | Damaged front o-ring | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Excessive cleanoff air when fluid valves are closed and gun is triggered | Damaged/missing fluid housing o-ring | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Fluid does not shut off when fluid valves are closed | Damaged fluid valves | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Burst of air from muffler when gun is triggered | Normal | No action required |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Steady air leakage from muffler | Damaged air valve o-rings | Replace |
Damaged piston o-rings | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Air leakage from front air valve | Damaged air valve o-rings | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Air leak around lock ring | Damaged o-ring | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Cannot tighten retaining ring until it bottoms out | Air cap assembled before retaining ring | Install retaining ring first, then air cap |