Probler P2 Trouble Shooting
This article features a selection of common problems applicators have experienced with the Probler P2 spray gun along with the cause and solution.
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Gun does not actuate when triggered | Air switch assembly is closed | Open |
Plugged exhaust | Clean air ports in handle | |
Damaged trigger spool o-rings | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
There is no fluid spraying when the gun is fully actuated | Closed fluid valves | Open |
Plugged impingement ports | Clean | |
Plugged check valves | Clean |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Gun actuates slowly | Plugged exhaust | Clean air ports in handle |
Damaged piston o-rings | Replace | |
Dirty air valve, or damaged o-rings | Clean air valve or replace o-rings |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
There is a leakage between flat tip and mixing chamber | Tip is not seated properly | Reassemble |
Damaged or missing seal | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
There is a pressure imbalance | Plugged impingement ports | Clean |
Plugged check valves | Clean | |
Viscosities are not equal | Adjust temperature to compensate |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
There is A and/or B side fluid in the gun air section | Damaged side seals | Replace |
Damaged mixing chamber | Replace | |
Damaged side seal o-rings | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Fluid mist from mix chamber or air cap | Damaged side seals | Replace |
Damaged mix chamber | Replace | |
Damaged side seal o-rings | Replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
The fluid does not shut off when fluid valves are closed | Damaged fluid valves | Tighten packing or replace |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Burst of air from muffler when gun is triggered | Normal | No action required |
SYMPTOM | CAUSE | SOLUTION |
---|---|---|
Steady air leakage from muffler | Damaged air valve o-rings | Replace |
Damaged piston o-rings | Replace |